Enhanced disinfection with hybrid hydrogen peroxide fogging in a critical care setting | BMC Infectious Diseases | Full Text

2022-10-01 09:09:47 By : Ms. Apple liu

BMC Infectious Diseases volume  22, Article number: 758 (2022 ) Cite this article

Environmental contamination contributes to hospital associated infections, particularly those caused by multi-drug resistant organisms (MDRO). This study investigated bioburden presence on surfaces in a critical care center’s patient rooms following typical environmental services (EVS) practices and following intervention with hybrid hydrogen peroxide™ (HHP™) fogging.

Upon patient discharge, following standard cleaning or cleaning with ultraviolet (UV) light use, patient rooms were sampled by swabbing for adenosine triphosphate (ATP) and aerobic colony counts (ACC) from five preset locations. Rooms were then fogged via HHP technology using chemical indicators and Geobacillus stearothermophilus biological indicators for sporicidal validation monitoring. Following fogging, rooms were sampled again, and results were compared.

A 98% reduction in ACC was observed after fogging as compared to post EVS practices both with and without UV light use. No statistical difference was seen when comparing cleaning to cleaning with UV light use. Methicillin-resistant Staphylococcus aureus (MRSA) and Pseudomonas aeruginosa were identified following EVS practices and not detected following HHP fogging. ATP samples were reduced 88% by fogging application. Chemical and biological indicators confirmed correct application of HHP fogging, as seen through its achievement of a 6-log reduction of bacterial spores.

HHP fogging is a thorough and efficacious technology which, when applied to critical care patient rooms, significantly reduces bioburden on surfaces, indicating potential benefits for implementation as part of infection prevention measures.

Despite ongoing efforts to advance strategies for infection control, the challenge of preventing hospital associated infections (HAIs), particularly those caused by multi-drug resistant organisms (MDROs), persists in healthcare today. In a prevalence study conducted at 1,150 centers across 88 countries the overall rate of suspected or confirmed infection of intensive care unit (ICU) patients was 54%, higher than rates seen in previous years [1]. A ten-year study of burn injuries in pediatric patients attributed 54% of deaths to sepsis, with 73% of these caused by MDROs, of which 64% was attributed to Pseudomonas aeruginosa alone [2]. Patients with large burns are not only more susceptible to infection but, once infected, are more likely to shed infectious pathogens into their environment, perpetuating the contamination in burn units [3]. Once shed into the environment, organisms such as Clostridioides difficile (C. diff), methicillin-resistant Staphylococcus aureus (MRSA), Acinetobacter baumannii, and P. aeruginosa can survive on dry surfaces for extended time periods and are difficult to eradicate even with terminal cleaning protocols [4].

The link between environmental contamination, or bioburden, and acquired infection rates has been well studied [5,6,7]. Residues left by cleaning chemicals combined with organic biofilms contribute to contaminated surfaces by acting as protective reservoirs for pathogens [5, 8], with an estimated 20% of HAIs caused by transmission from environmental surfaces [9]. Two common ways healthcare facilities measure for the presence of contamination on surfaces are monitoring bioburden through adenosine triphosphate (ATP) and swabbing for aerobic colony counts (ACC) [6, 10, 11]. Although results are less rapid, ACC swabs give a more defined picture of viable bacterial presence, and high rates of these aerobic bacterial colonies have been shown to coincide with higher risk for HAIs. [10, 11]

Considering the necessity for reducing or eliminating the presence of pathogens in the patient’s environment, a novel disinfection technology, hybrid hydrogen peroxide™ (HHP™) fogging was introduced to examine its potential effects on bioburden relative to current facility practices. The HHP system delivers a hybrid mixture of vaporous and micro-aerosolized hydrogen peroxide fog via pulse technology. This novel fogging delivery accounts for naturally decomposing hydrogen peroxide by periodically replenishing the HHP fog during the disinfection cycle. This patented delivery system automatically induces the fogging dwell time, the time needed for the hydrogen peroxide fog to achieve maximum efficacy. The HHP system has demonstrated efficacy against potential HAI pathogens such as S. aureus and C. difficile. [12,13,14,15] While commonly mistaken in the healthcare environment to be equivalent in efficacy to technologies such as ultraviolet (UV) light, literature demonstrates HHP fogging and similar hydrogen peroxide (H2O2) technologies have significantly higher disinfection potential [12,13,14,15,16,17,18,19] combatting pathogens, such as C. difficile, norovirus, S. aureus, and others, including in the presence of biofilms and soil loads [13, 15, 20]. However, the impact and efficacy of HHP fogging on environmental contamination in patient rooms in a healthcare setting has not yet been measured. This work aims to examine the introduction of HHP technology in a critical care environment, quantified by ACC and ATP, and to evaluate its efficacy in countering nosocomial multi-resistant pathogens beyond currently employed practices.

This study was undertaken in the northeast United States at a regional hospital. With over 250 annual admissions and a 6-day average length of stay, this facility’s verified adult and pediatric burn center presented a unique opportunity due to the inherent vulnerability to infection of patients recovering from burn injuries [2]. The intent of this study was to quantify potential reductions in environmental contamination through implementation of HHP fogging compared to Environmental Services (EVS) practices of standard cleaning (SC) or cleaning followed by UV light use (SC + UV), as measured by ACC and ATP. Similar to autoclaving and other sterilization procedures, HHP technology is measured with the inactivation of spore-carrying biological indicators (BIs) consistent with international standards [21]. Indicators are populated with a non-harmful colony of Geobacillus stearothermophilus (1 × 106 and 2.2 × 106 organisms) which can be disinfected alongside room surfaces giving a visible confirmation of sporicidal efficacy and providing confidence in the inactivation of lesser-resistant pathogens as well [22, 23].

Certified staff from a third-party disinfection service (ForTec Medical; Hudson, OH) conducted environmental sampling and HHP fogging implementation. Data was collected from within single occupancy patient rooms following occupancy of greater than 10 days. EVS staff performed either SC, or, for rooms where the patient had a positive MDRO culture, SC + UV (Moonbeam UVC; Diversey; Fort Mill, SC) in 2–3 locations for 3–5 min per location in accordance with manufacturer guidance [24]. Disinfection chemicals employed in these practices included: a quaternary ammonium-based product (Virex II 256; Diversey; Fort Mill, SC) marketed as a hospital grade one-step disinfectant cleaner and deodorizer (EPA 70627-24), an alcohol-based glass and surface cleaner (Glance; Diversey; Fort Mill, SC), a floor cleaner degreaser (Prominence; Diversey; Fort Mill, SC), and hydrogen peroxide wipes (Oxivir; Diversey; Fort Mill, SC) employed as needed.

Environmental sampling was performed before patient room re-occupation within 3 h of EVS practices. Swabs (Enviro swabs; 3 M; St. Paul, MN) were collected from 5 preset surfaces within the patient room: telephone, bed rail, touch screen monitor, toilet seat, and bathroom sink backsplash. Locations were selected spanning the room and adjoining bathroom in potential contact points for patients, staff, or visitors. Swabbed locations and room configuration are shown in Fig. 1. Approximately half of the rooms (7 rooms, 33–35 swabs) were sampled following SC + UV, with seven additional rooms (33–35 swabs) following SC. UV light use in the remaining three rooms was not recorded. Swabbed locations were irregular in shape, however best efforts were made to adhere to a surface area of approximately 100 cm2. For each swab, 25 swabbing movements were applied horizontally, vertically, and diagonally. Collected swabs were closed, sealed with paraffin tape, and maintained at 35–46°F (2–8 °C). ATP swabs (Neogen; Lansing, MI) were collected from an approximate 4 inch × 4 inch square (10 × 10 cm2) area of countertop adjacent to the room sink. This location was also chosen as a potential contact point, furthering the distribution of swabbed surfaces within the patient room (Fig. 1). Swabs were analyzed in the accompanying ATP Accupoint Advanced Reader (Neogen; Lansing, MI) and results recorded.

Five H2O2 chemical indicators (CIs) (3 M; St. Paul, MN) were placed throughout the room to monitor the dispersion of HHP fog. G. stearothermophilus BIs (1 × 106 spores; Crosstex; Rush, NY) and (2.2 × 106 spores; Mesa; Lakewood, CO) on steel carriers were employed as a measurement for determining adherence to the fogging protocol, failure constituting the exclusion criteria for this study. Indicators were placed throughout the room in three locations selected to challenge the HHP fog dispersion: forward of the fogging device (room sink), above and behind (patient shelf), indirect in the adjacent room (bathroom) (Fig. 1). A room could be sampled more than once if the room was reoccupied and again met the inclusion criteria.

Data Collection Locations. This diagram of a patient room shows approximate locations where each data type was collected as well as the location of the hybrid hydrogen peroxide (HHP) fogging device. Wheeled patient beds were rotated to increase fogging access throughout the room, and returned to position following fogging. Swabbed locations ranged approximately 1 ft (0.3 m) to 10 ft (3 m) from the HHP device. Methicillin-resistant Staphylococcus aureus detected approximately 8 ft (2.4 m) from the HHP device was not detected following HHP fogging

The HHP disinfection system consists of a 7% H2O2 solution (CURoxide™ sporicidal disinfectant EPA#93324-1) paired with the CURIS portable fogging device (EPA#93324-1 CURIS System; Oviedo, FL) which together produce HHP fog. The HHP device was placed in the room along with dissipation devices (Dri-Eaz; Burlington, WA; Lasko; West Chester, PA). Dissipation devices are automatically initiated by the HHP device after the HHP cycle is complete to enhance the decomposition of any remaining HHP fog, increasing the speed at which the room is returned to initial environmental conditions. Environmental conditions were monitored to confirm the operating range ≤ 70°F (21 °C) and 25–55%Rh (Amprobe THWD-3; Everett, WA). Heating ventilation and air conditioning (HVAC) airflow was turned off, vent covers employed, doors were closed and visible gaps taped to stop air flow. Prior to the start of the study period, room dimensions for the burn center were measured from facility diagrams and dimensions were recorded in the HHP device’s data management software by the technician or authorized personnel. HHP cycle parameters were determined by room volume accounting for the drop ceiling, as calculated by the device’s software. The fogging cycle was initiated remotely from outside the room via an electronic tablet through the CURIS Decon application (app). HHP device cycle time for the rooms of this burn center averaged 42 min. Following cycle completion, the dissipation devices were initiated by the HHP device. H2O2 levels were monitored with a portable hand-held device (Dräger X-am 5100; Drager; Lübeck, DE) prior to safe re-entry.

Following dissipation, swabbing samples were collected in the same manner in immediately adjacent locations to the initial swabs. Swabs were vortexed, eluted onto tryptic soy agar plates in triplicate, incubated at 36 °C (96.8°F) for 48 h and ACC results recorded. Swabs were additionally plated on organism-specific chromogenic media (CHROMagar; Paris, FR) for identification of MRSA and P. aeruginosa.

CIs were collected, analyzed, and recorded. BIs were transferred into tryptic soy broth (Crosstex; Rush, NY & Mesa; Lakewood CO), incubated for 7 days at 60 °C (140°F), observed for turbidity or color change indicating growth, and results recorded. Positive BI controls accompanied each BI lot to verify viability. Challenged (exposed to HHP fog) BIs were used as a benchmark for proper sporicidal protocol and process.

Data generated from the HHP device including room parameters, HHP dosage, and cycle duration, uploaded automatically to the online data management system, and service reports were generated from that system. Information on patient length of stay and presence of MDRO (if known) was recorded. ATP results were compared post EVS practices (SC and SC + UV) and post HHP fogging. A two-sample t-test was performed to compare the non-normally distributed ATP RLU values. ACC swab results were analyzed using GraphPad Prism version 9.1.0 for Windows (GraphPad Software; San Diego, CA). The Mann–Whitney test was used to analyze post EVS and post fogging, and the Kruskal Wallis test for significance between SC, SC + UV, and post HHP fog.

During the study period of December 2020 through May 2021, 17 patient rooms were sampled. Inclusion criteria for the study was not met on three occasions when HHP fogging protocols were not followed. On these occasions data following EVS practices were unaffected and thus included in the analysis; however, no further comparison to after-HHP fogging could be made. On all other swabbing occasions, results including swabs with a non-detection were included. Patient room occupancy prior to discharge averaged 23.6 days with no detectable correlation between days occupied and baseline ACC levels (simple regression analysis, R2 = 0.04, p = 0.49). Average center occupancy was 6.5 patients, with a maximum occupancy of 12.

A total of 150 ACC swabs were collected (82 post EVS, 68 post fogging). Following EVS practices (SC and SC + UV), 5 swabbed surfaces ranged from 0 to 153 ACC (mean 8.357 ACC, SD = 21; median 1.17 ACC). 63.4% of samples detected bacterial presence, with 85% of these demonstrating a result greater than or equal to 1 ACC. Following HHP fogging, ACC ranged from 0 to 1.33 ACC (mean 0.137 ACC, SD = 0.295; median 0 ACC) for a further reduction of 98% compared to post EVS practices (Mann Whitney test p < 0.0001) (Fig. 2). 23.5% of samples detected bacterial presence with only one sampled location averaging greater than 1 ACC (1.3 ACC). To evaluate the impact of UV light use (SC + UV) relative to standard cleaning (SC), HHP fogging, or any cumulative effect (SC + UV followed by HHP fog), data from these groups was compared using a Kruskal Wallis, uncorrected Dunn’s test. Application of HHP fog was statistically different from both SC and SC + UV (p = 0.0002 and p < 0.0001, respectively). However, there was no statistical difference between standard cleaning (SC) and UV light use (SC + UV) (p = 0.186).

Measurements of Disinfection Interventions. Aerobic colony counts (ACC) following each applied intervention in relation to 1 ACC. Data show one collection below 1 ACC following standard cleaning (SC), and one collection below 1 ACC following cleaning with UV light use (SC + UV). All ACC averages following hybrid hydrogen peroxide (HHP) fogging fell below 1 ACC

MRSA was detected on five sampling occasions, following both SC and SC + UV (mean 0.1788 ACC, SD = 1.298). Four of the five occasions with MRSA results met the inclusion criteria and demonstrated a 100% reduction of MRSA (Table 1). Of the 82 total samples collected, samples positive for MRSA represented 6.1%. P. aeruginosa was detected twice following EVS practices (mean 0.1545, SD = 1.399). This small sample size did not allow for a full statistical analysis, however the swabbing occasion with the maximum value of 12.67 colonies was reduced 100% following fogging. P. aeruginosa represented 2.44% of the overall collected samples.

Following EVS practices (SC and SC + UV), mean ATP results were 9,021 (SD = 9,780) relative light units (RLU). Following HHP fogging, ATP averaged 1,109 RLU (SD = 855) for an overall average reduction of 88%. A two-sampled t-test revealed a statistically significant difference in mean RLU after EVS practices and RLU following HHP fogging (p = 0.013).

Beginning with swabbing occasion 12, the number of BIs was reduced as there was a national shortage of available indicators due to the need to validate disinfection processes during the COVID-19 pandemic. For rooms including two BIs, the forward location adjacent to the room sink was excluded as the other two locations were thought to represent a greater challenge to inactivation of the BIs. Sample occasions 14–17 employed one BI as previously described and one indicator with a G. stearothermophilus population of 2.2 × 106, where the higher population indicator was placed on the shelf. There were three instances of BI failures coinciding with a failure of fogging protocol. No other failed indicators were observed, for a total of 37 of 43 indicators demonstrating a greater than 6-log sterilization of challenged indicators. 85 CIs were collected over the course of study. CIs consistently demonstrated hydrogen peroxide exposure in the farthest reaches of each room, even in rooms where BI failures occurred.

To meet the need for disinfecting environmental surfaces, an ever-increasing amount of disinfection technologies are available, however, not all types of advanced disinfection tools are similar in their outcome. While these differences in efficacy are demonstrated across a bulk of research [15, 18, 19], the damaging perception remains, leading to ineffective disinfection practices despite the cost and effort of implementation. The range of present pathogens is approached in a uniform manner, which ignores differences in their susceptibility to disinfectants [5, 23, 25], and important pathogenic behavior such as the potential for environmental persistence and bacterial regrowth [4, 5, 7, 8, 26]. Given the increased tolerance to disinfection of bacteria within biofilms over isolated bacterium [5, 8, 27], as well as the ability of organisms in biofilms to confer antibiotic resistance [5, 8, 27, 28], this oversight could have serious consequences such as rapid regrowth to an infectious dose [26, 29] or development of disinfectant resistance [27]. Even non-chemical disinfection technologies such as UV light can result in a lesser log reduction of pathogens [18, 19, 30]. In light of the severity of outcome and resulting high mortality rates caused by infection with an MDRO [2, 3], infection control practices intended to remove the risks posed by contaminated environmental surfaces must reach beyond a partial disinfection and target a complete eradication of environmental pathogens.

These results were evaluated to compare the effects of HHP fogging to current facility practices, demonstrating HHP significantly reduced environmental contamination. Following HHP fogging, ACC in patient rooms dropped 98% from levels post SC and SC + UV, consistently averaging less than one colony count. All locations where MRSA was identified post EVS practices were negative for MRSA following HHP fogging. These results in combination with laboratory testing [12, 13] showing efficacy against S. aureus possibly indicate this process is effective in combating MRSA, however due to the small sample size, further investigation is merited. Likewise, on the swabbing occasion with the greatest detected colony count, P. aeruginosa was reduced from 12.6 ACC following EVS practices to 0 ACC following HHP fogging. This study was not powered to evaluate HHP fogging’s impact on HAIs, though the reduction of identified bacterial environmental contamination (a known factor in HAIs) is promising.

The ACC data collected following SC and SC + UV reflected a wide variance in bacterial levels, with 63.4% of tested surfaces remaining contaminated. This finding is neither unexpected nor surprising, as it is well understood that manually applied cleaning methods are inherently imperfect despite best application efforts [11]. The further comparison of SC + UV rooms versus SC rooms showed no statistically significant difference in ACC levels, which may be in accordance with known challenges affiliated with UV light use, such as shadows, run time, and distance [19, 30]. Further, MRSA was detected on five occasions and P. aeruginosa on two occasions, irrespective of UV light application, affirming the known difficulties in eliminating these common pathogens. MDRO’s survivability as well as rapid propagation create particular risk of infection for the subsequent room occupant, emphasizing the importance of achieving their elimination [11].

Biological indicators introduced into the room to monitor the HHP fogging cycle repeatedly resulted in successful inactivation demonstrating sporicidal efficacy of the disinfection treatment and indicating efficacy against less hardy pathogens [16, 22, 23]. The HHP system has been effective against C. difficile spores in a three-part soil load [14, 15], which, in combination with the sporicidal efficacy seen in this study, suggests that it may likewise be used for combatting the fastidious and pathogenic C. difficile in a healthcare environment. On three occasions, a less than 6-log reduction of one or more indicators coincided with failures in adherence to fogging protocols which require airflow control within the room for the duration of the fogging cycle. Fogging technologies must be contained within the room to achieve optimal contact of the disinfectant. Incomplete vent coverage as well as activation of the facility’s HVAC before HHP cycle completion did not allow for optimal contact. These results demonstrate the transparency of biological efficacy in real time and confirm the applicability of BIs as an effective tool for monitoring the proper use of this technology.

Despite rigid cleaning protocols and heightened awareness of infection risks in a critical care environment, including burn units, ATP levels post EVS practices were consistently found to be high [31]. While ATP is a practical measurement tool, RLU indicates a measure of organic presence, but it is unable to distinguish between pathogenic organisms and other organic materials and can be influenced by cleaning chemicals and their residues [11, 32]. High ATP readings may therefore be a combination of chemical and biological factors, possibly indicating the presence of biofilms and residues which can promote pathogen reservoirs [5, 8, 11, 27]. Post HHP fogging, ATP RLUs were reduced in every room, which is particularly notable as no wiping of the surface took place between swabbing. The observed reduction therefore could be due to biological breakdown, chemical residues, or a combination of these factors. Though lacking in specificity, measurements of ATP are commonly used as a monitoring tool for environmental cleanliness in healthcare facilities, due in part to the ability to obtain rapid results. ATP swabbing was included in this study design for its relevance to other facilities and existing literature [31].

The reduction in ACC, and ATP RLU’s are strong indications that bioburden present after EVS practices have been inactivated or reduced by HHP fogging to levels associated with a risk reduction for HAIs from environmental surfaces [11, 31, 33]. In addition to being effective against difficult to kill pathogens [15], HHP fogging presents an inherent advantage in terms of whole room dispersal [17] and reaching areas where wiping alone or UV light may not adequately reach [30]. The results presented emphasize HHP fogging achieves more efficacious disinfection of room surfaces than manual cleaning and UV light application combined.

There are some limitations to this study. Though typical patient volumes were seen, the time period studied overlapped with enhanced cleaning practices in response to the COVID-19 pandemic, limiting the ability to compare these results with those of a similar time period. In consideration of the enhanced demands placed on the environmental services team during the pandemic, the EVS staff was not blinded for the purposes of this study. This awareness may have influenced the individual practices of staff members. This study focused on efficacy of outcome as the most important consideration for disinfection practices. Due to the additional time needed to collect samples and place indicators to determine efficacy, the time needed for each disinfection intervention was not recorded, though may be of interest. The facility’s application of UV light following known MDRO cases enabled comparisons presented here; however, additional head-to-head investigations would be of interest to aid in the understanding that disinfection technologies have wide ranges in achievable efficacy, particularly in real-world applications. Though detected, the small sample size of MRSA and P. aeruginosa limited the ability to draw statistical inferences despite the data that was obtained. Further study regarding disinfection of these and other epidemiologically important pathogens in the healthcare setting is needed. Although this testing targeted bacterial counts as well as specific pathogens, a further investigation into the impact of HAIs within the tested department is warranted.

In closing, this study examined patient rooms of a critical care center, finding that HHP fogging following current EVS practices, with or without UV light use, resulted in a significant reduction in bacterial presence on the environmental surfaces. The confirmed sporicidal efficacy may denote significantly lower risk posed by environmental contamination and play an important role in preventing HAIs. This real-world application of HHP fogging demonstrates a thorough and efficacious treatment method for patient spaces, indicating integration of HHP technology in hospitals could further enhance infection prevention.

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Standard cleaning with UV light use

Vincent JL, Sakr Y, Singer M, et al. Prevalence and outcomes of infection among patients in intensive care units in 2017. JAMA. 2020;323(15):1478–87. https://doi.org/10.1001/jama.2020.2717.

Article  PubMed  PubMed Central  Google Scholar 

Williams FN, Herndon DN, Hawkins HK, et al. The leading causes of death after burn injury in a single pediatric burn center. Crit Care. 2009;13(6):R183. https://doi.org/10.1186/cc8170.

Article  PubMed  PubMed Central  Google Scholar 

Weber J, McManus A. Nursing Committee of the International Society for Burn Injuries. Infection control in burn patients. Burns. 2004;30(8):A16-24. https://doi.org/10.1016/j.burns.2004.08.003.

Otter JA, Yezli S, French GL. The role played by contaminated surfaces in the transmission of nosocomial pathogens. Infect Control Hosp Epidemiol. 2011;32(7):687–99. https://doi.org/10.1086/660363.

Bowler P, Murphy C, Wolcott R. Biofilm exacerbates antibiotic resistance: Is this a current oversight in antimicrobial stewardship? Antimicrob Resist Infect Control. 2020;9:162. https://doi.org/10.1186/s13756-020-00830-6.

Article  PubMed  PubMed Central  Google Scholar 

Dancer SJ. The role of environmental cleaning in the control of hospital-acquired infection. J Hosp Infect. 2009;73(4):378–85. https://doi.org/10.1016/j.jhin.2009.03.030.

CAS  Article  PubMed  Google Scholar 

Faires MC, Pearl DL, Berke O, Reid-Smith RJ, Weese JS. The identification and epidemiology of methicillin-resistant Staphylococcus aureus and Clostridium difficile in patient rooms and the ward environment. BMC Infect Dis. 2013;13(1):342. https://doi.org/10.1186/1471-2334-13-342.

Article  PubMed  PubMed Central  Google Scholar 

Richardson LA. Understanding and overcoming antibiotic resistance. PLos Biol. 2017;15(8): e2003775. https://doi.org/10.1371/journal.pbio.2003775.

CAS  Article  PubMed  PubMed Central  Google Scholar 

Weinstein RA. Epidemiology and control of nosocomial infections in adult intensive care units. Am J Med. 1991;91(32):S179–84. https://doi.org/10.1016/0002-9343(91)90366-6.

Dancer SJ, White L, Robertson C. Monitoring environmental cleanliness on two surgical wards. Int J Environ Health Res. 2008;18:357–64. https://doi.org/10.1080/09603120802102465.

Carling PC, Bartley JM. Evaluating hygienic cleaning in health care settings: what you do not know can harm your patients. Am J Infect Control. 2010;38:S41-50. https://doi.org/10.1016/j.ajic.2010.03.004.

Walden M. Association of Official Agricultural Chemists Germicidal Spray Products Test. Proprietary GLP laboratory report. 2017. Available from: https://www.curissystem.com [Accessed: 2021–09–30].

U.S. Environmental Protection Agency. CURoxideTM Master Label. EPA Reg. No. 93324-1. Washington D.C.: GPO, 2020. https://www3.epa.gov/pesticides/chem_search/ppls/093324-00001-20200716.pdf.

Richard E. Evaluation of Surface Room Disinfection via Fogging Device Against C. difficile. Proprietary GLP laboratory report. 2019. Available from: https://www.curissystem.com [Accessed: 2021–03–28].

U.S. Environmental Protection Agency. List K: EPA’s Registered Antimicrobial Products Effective Against Clostridium difficile Spores. Washington D.C.: GPO, 2021. https://www.epa.gov/sites/default/files/2021-02/documents/02-22-2021_list-k.pdf [Accessed: 2022–06–08].

Derr T, James M, Kuny C, et al. Aerosolized hydrogen peroxide decontamination of N95 respirators, with fit-testing and virologic confirmation of suitability for re-use during the COVID-19 pandemic. medRxiv. 2020. https://doi.org/10.1101/2020.04.17.20068577v1.

Henneman JR, McQuade EA, Sullivan RR, Downard J, Thackrah A, Hislop M. Analysis of range and use of a hybrid hydrogen peroxide system for biosafety level 3 and animal biosafety level 3 agriculture laboratory decontamination. Appl Biosaf. 2022;27(1):7–14. https://doi.org/10.1089/apb.2021.0012.

Article  PubMed  PubMed Central  Google Scholar 

Beswick AJ, Fry C, Bradley CR, et al. Automated room decontamination: report of a Healthcare Infection Society Working Party. J Hosp Infect. 2022. https://doi.org/10.1016/j.join.2022.01.006.

Havill N, Moore B, Boyce J. Comparison of the microbiological efficacy of hydrogen peroxide vapor and ultraviolet light processes for room decontamination. Infect Control & Hosp Epidemiol. 2012;33(5):507–12. https://doi.org/10.1086/665326.

Aliucci J, et al. Effective Penetration of Dry Biofilm through Pulse Hydrogen Peroxide. National Institute of Health (NIH); NSF. 2019. Available from: https://www.curissystem.com/resources/white-papers [Accessed: 2022–06–11].

U.S. Environmental Protection Agency (EPA) Office of Pesticide Programs. Protocol for Room Sterilization by Fogger Application. Washington D.C.: GPO, 2019. Available from: https://www.epa.gov/pesticide-registration/protocol-room-sterilization-fogger-application [Accessed 2021–05–22].

Sattar SA. Hierarchy of susceptibility of viruses to environmental surface disinfectants: a predictor of activity against new and emerging viral pathogens. J AOAC Int. 2007;90(6):1655–8. https://pubmed.ncbi.nlm.nih.gov/18193744/.

Spaulding EH. Chemical disinfection of medical and surgical materials. In: Lawrence C, Block SS, editors. Disinfection, sterilization, and preservation. Philadelphia (PA): Lea & Febiger; 1968. p. 517–31.

MoonBeam 3 [Internet]. Diversey.com. [cited 2021 Oct 6]. Available from: https://diversey.com/en/solutions/infection-prevention/uv-c-disinfection/moonbeam-3 [Accessed: 2021–03–28].

Sundheim G, Langsrud S, Heir E, Holck AL. Bacterial resistance to disinfectants containing quaternary ammonium compounds. Int Biodeterior Biodegradation. 1998;41(3–4):235–9. https://doi.org/10.1016/S0964-8305(98)00027-4.

Pray L. Antibiotic resistance, mutation rates and MRSA. Nat Educ. 2008;1(1):30. https://www.nature.com/scitable/topicpage/antibiotic-resistance-mutation-rates-and-mrsa-28360/.

Sorg RA, Lin L, van Doorn GS, Sorg M, Olson J, Nizet V, et al. Collective resistance in microbial communities by intracellular antibiotic deactivation. PLoS Biol. 2016;14(12):e2000631. https://doi.org/10.1371/journal.pbio.2000631.

CAS  Article  PubMed  PubMed Central  Google Scholar 

Hennequin C, Aumeran C, Robin F, Traore O, Forestier C. Antibiotic resistance and plasmid transfer capacity in biofilm formed with a CTX-M-15-producing Klebsiella pneumoniae isolate. J Antimicrob Chemother. 2012;67(9):2123–30. https://doi.org/10.1093/jac/dks169.

CAS  Article  PubMed  Google Scholar 

Onyango LA, Alreshidi MM. Adaptive metabolism in staphylococci: survival and persistence in environmental and clinical settings. J Pathog. 2018;2018:1092632. https://doi.org/10.1155/2018/1092632.

CAS  Article  PubMed  PubMed Central  Google Scholar 

Boyce JM, Farrel PA, Towle D, et al. Impact of room location on UV-C irradiance and UV-C dosage and antimicrobial effect delivered by a mobile UV-C light device. Infect Control Hosp Epidemiol. 2016;37:667–72. https://doi.org/10.1017/ice.2016.35.

Article  PubMed  PubMed Central  Google Scholar 

Nante N, Ceriale E, Messina G, Lenzi D, Manzi P. Effectiveness of ATP bioluminescence to assess hospital cleaning: a review. J Prev Med Hyg. 2017;58(2):E177–83 (PMID: 28900359).

CAS  PubMed  PubMed Central  Google Scholar 

Omidbakhsh N, Ahmadpour F, Kenny N. How reliable are ATP bioluminescence meters in assessing decontamination of environmental surfaces in healthcare settings? PLoS ONE. 2014;9(6):e99951. https://doi.org/10.1371/journal.pone.0099951.

CAS  Article  PubMed  PubMed Central  Google Scholar 

Huang Y-S, Chen Y-C, Chen M-L, Cheng A, Hung I-C, Wang J-T, et al. Comparing visual inspection, aerobic colony counts, and adenosine triphosphate bioluminescence assay for evaluating surface cleanliness at a medical center. Am J Infect Control. 2015;43(8):882–6. https://doi.org/10.1016/j.ajic.2015.03.027.

CAS  Article  PubMed  Google Scholar 

The authors wish to thank Lori Sampsel, Tami Kline, Heather Belacic and their teams for their hard work and coordination, Justin Hughes and Kelly Varney for their diligence, logistical support and data collection, and Jodi Woodson for her editorial contributions.

Funding and data collection for this research was provided by ForTec Medical, a third-party company. The funders had no role in analysis, decision to publish, or preparation of the manuscript, nor do the funders have any commercial relationship with the use of the tested equipment. The funder’s intent in funding this study was to evaluate the efficacy and outcome of the tested disinfection system. Dr. Christine Greene provided consultation and statistical analysis on collected data for the third-party company funding the study. No other authors received direct or indirect financial support for the research, authorship, and/or publication of this article.

Department of Surgery, Division of Burn Surgery, Paul and Carol David Foundation Burn Institute, Akron Children’s Hospital, Akron, OH, USA

Department of Surgery and Pediatrics, NEOMED, Rootstown, OH, USA

Department of Construction, Facilities and Public Safety, Akron Children’s Hospital, Akron, OH, USA

Department of Infection Prevention and Control, Akron Children’s Hospital, Akron, OH, USA

Department of Executive Management, CURIS System, 610 Kane Court, Oviedo, FL, 32765, USA

Department of Scientific Research, CURIS System, 610 Kane Court, Oviedo, FL, 32765, USA

Ramboll Group, Ramboll USA, Inc., 4245 North Fairfax Drive, Suite 700, Arlington, VA, 22203, USA

Department of Quality Services and Division of Pediatric Critical Care, Department of Pediatrics, Akron Children’s Hospital, Akron, OH, USA

Department of Pediatrics, NEOMED, Rootstown, OH, USA

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

All authors contributed to and approved the study design. CG conducted the statistical analysis. All authors contributed to interpretation of the data and the writing of the manuscript. All authors read and approved the final manuscript.

No ethics approval was needed for this research.

All authors have approved this manuscript and its submission.

Authors AK, BL, TB, MB, and CG declare no potential conflicts of interest with respect to the research, authorship, and/or publication of this article. Authors FG and MH are employed by CURIS System and provided training and support on use of the tested equipment. FG and MH did not collect nor analyze the data in this manuscript. All authors have submitted the ICMJE form for Disclosure of Potential Conflicts of Interest.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Khandelwal, A., Lapolla, B., Bair, T. et al. Enhanced disinfection with hybrid hydrogen peroxide fogging in a critical care setting. BMC Infect Dis 22, 758 (2022). https://doi.org/10.1186/s12879-022-07704-9

DOI: https://doi.org/10.1186/s12879-022-07704-9

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

By using this website, you agree to our Terms and Conditions, California Privacy Statement, Privacy statement and Cookies policy. Manage cookies/Do not sell my data we use in the preference centre.

© 2022 BioMed Central Ltd unless otherwise stated. Part of Springer Nature.